0 CART
items in your cartto quote Checkout
Ooops no items were found.
Try something else.
Ok
Loading…

1504G42-01 - 12-2 BN GY GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 250' Coil, Type AC - Health Care Facilities

Picture of 1504G42-01 - 12-2 BN GY GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 250' Coil, Type AC - Health Care Facilities Picture of 1504G42-01 - 12-2 BN GY GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 250' Coil, Type AC - Health Care Facilities
Picture of 1504G42-01 - 12-2 BN GY GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 250' Coil, Type AC - Health Care Facilities Picture of 1504G42-01 - 12-2 BN GY GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 250' Coil, Type AC - Health Care Facilities

1504G42-01 - 12-2 BN GY GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 250' Coil, Type AC - Health Care Facilities

Item Code: 716160
Manufacturer Ref HCF122277V
Minimum order quantity 250
Call for Availability
Compare

Description

HCF-90®, which features interlocked steel armor, is a derivative of Type AC Cable. It was introduced in the 1980s to support NEC Article 517 on Healthcare Facilities in "areas of patient care". This branch circuit cable is offered in 12 or 10 AWG THHN in 2, 3, or 4 conductors and was one of the original ColorSpec® ID cables. The green interlocked armor became the recognized standard for healthcare facilities' cables, where redundant grounding is required. These 600V cables with THHN conductors have two paths to ground, which is a requirement of NEC 517. The outer metal jacket, in combination with a 16AWG, serves as one equipment grounding means, while the second is an additional full-size green copper ground.

Specifications

Weight

58.7lb

Height

0.54mm

Width

0.54mm

Length

3000mm

Brand

General Wire

Category

CU Interlocked Steel Armor Cables - Teck

Conductor Size

12 AWG

Conductor Type

Solid Copper

Insulation Material

THHN

Jacket Color

Green

Jacket Material

Interlocked Galvanized Steel Strip

Length

250 ft

Number of Conductors

2

Outside Diameter

0.535 in

Packaging Type

Coil

Temperature Rating

90 deg C

Type

Type AC

Voltage Rating

600 V AC

1504G42-01 - 12-2 BN GY GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 250' Coil, Type AC - Health Care Facilities

Picture of 1504G42-01 - 12-2 BN GY GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 250' Coil, Type AC - Health Care Facilities Picture of 1504G42-01 - 12-2 BN GY GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 250' Coil, Type AC - Health Care Facilities
Picture of 1504G42-01 - 12-2 BN GY GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 250' Coil, Type AC - Health Care Facilities Picture of 1504G42-01 - 12-2 BN GY GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 250' Coil, Type AC - Health Care Facilities

1504G42-01 - 12-2 BN GY GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 250' Coil, Type AC - Health Care Facilities

Item Code: 716160
Manufacturer Ref HCF122277V
Minimum order quantity 250
Call for Availability
Compare

Description

HCF-90®, which features interlocked steel armor, is a derivative of Type AC Cable. It was introduced in the 1980s to support NEC Article 517 on Healthcare Facilities in "areas of patient care". This branch circuit cable is offered in 12 or 10 AWG THHN in 2, 3, or 4 conductors and was one of the original ColorSpec® ID cables. The green interlocked armor became the recognized standard for healthcare facilities' cables, where redundant grounding is required. These 600V cables with THHN conductors have two paths to ground, which is a requirement of NEC 517. The outer metal jacket, in combination with a 16AWG, serves as one equipment grounding means, while the second is an additional full-size green copper ground.

Specifications

Weight

58.7lb

Height

0.54mm

Width

0.54mm

Length

3000mm

Brand

General Wire

Category

CU Interlocked Steel Armor Cables - Teck

Conductor Size

12 AWG

Conductor Type

Solid Copper

Insulation Material

THHN

Jacket Color

Green

Jacket Material

Interlocked Galvanized Steel Strip

Length

250 ft

Number of Conductors

2

Outside Diameter

0.535 in

Packaging Type

Coil

Temperature Rating

90 deg C

Type

Type AC

Voltage Rating

600 V AC

SEARCH ×