0 CART
items in your cartto quote Checkout
Ooops no items were found.
Try something else.
Ok
Loading…

1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities

Picture of 1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities Picture of 1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities
Picture of 1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities Picture of 1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities
Picture of 1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities Picture of 1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities
Picture of 1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities Picture of 1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities

1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities

Item Code: 646955
Manufacturer Ref HCF123R
Minimum order quantity 1000
Call for Availability
Compare

Description

HCF-90®, which features interlocked steel armor, is a derivative of Type AC Cable. It was introduced in the 1980s to support NEC Article 517 on Healthcare Facilities in "areas of patient care". This branch circuit cable is offered in 12 or 10 AWG THHN in 2, 3, or 4 conductors and was one of the original ColorSpec® ID cables. The green interlocked armor became the recognized standard for healthcare facilities' cables, where redundant grounding is required. These 600V cables with THHN conductors have two paths to ground, which is a requirement of NEC 517. The outer metal jacket, in combination with a 16AWG, serves as one equipment grounding means, while the second is an additional full-size green copper ground.

Specifications

Weight

279.2

Height

10

Width

24

Length

288

Brand

General Wire

Category

CU Interlocked Steel Armor Cables - Teck

Conductor Size

12 AWG

Conductor Type

Solid Copper

Insulation Material

THHN

Jacket Color

Green

Jacket Material

Interlocked Galvanized Steel Strip

Length

1000 ft

Number of Conductors

3

Outside Diameter

0.582 in

Packaging Type

Reel

Temperature Rating

90 deg C

Type

Type AC

Voltage Rating

600 V AC

1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities

Picture of 1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities Picture of 1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities
Picture of 1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities Picture of 1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities
Picture of 1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities Picture of 1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities
Picture of 1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities Picture of 1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities

1505G60-00 - 12-3 BK RD WE GN HCF-90®, Green Interlocked Galvanized Steel Armor with phase ID, 1000' Reel, Type AC - Health Care Facilities

Item Code: 646955
Manufacturer Ref HCF123R
Minimum order quantity 1000
Call for Availability
Compare

Description

HCF-90®, which features interlocked steel armor, is a derivative of Type AC Cable. It was introduced in the 1980s to support NEC Article 517 on Healthcare Facilities in "areas of patient care". This branch circuit cable is offered in 12 or 10 AWG THHN in 2, 3, or 4 conductors and was one of the original ColorSpec® ID cables. The green interlocked armor became the recognized standard for healthcare facilities' cables, where redundant grounding is required. These 600V cables with THHN conductors have two paths to ground, which is a requirement of NEC 517. The outer metal jacket, in combination with a 16AWG, serves as one equipment grounding means, while the second is an additional full-size green copper ground.

Specifications

Weight

279.2

Height

10

Width

24

Length

288

Brand

General Wire

Category

CU Interlocked Steel Armor Cables - Teck

Conductor Size

12 AWG

Conductor Type

Solid Copper

Insulation Material

THHN

Jacket Color

Green

Jacket Material

Interlocked Galvanized Steel Strip

Length

1000 ft

Number of Conductors

3

Outside Diameter

0.582 in

Packaging Type

Reel

Temperature Rating

90 deg C

Type

Type AC

Voltage Rating

600 V AC

SEARCH ×