JLLN040 - JLLN040 - JLLN Series

Picture of JLLN040 - JLLN040 - JLLN Series

JLLN040 - JLLN040 - JLLN Series

Item Code: 11549
Manufacturer Littelfuse
Manufacturer Ref JLLN040
Call for Availability
Compare

Description

Space saving POWR-GARD Class T fuses are the most compact fuses available in ratings above 30 amperes — less than one-third the size of comparable Class R fuses. When rated in accordance with the NEC, Class T fuses provide fast-acting overload and short circuit protection for non-inductive circuits and equipment. Used in inductive circuits, the ampere rating of Class T fuses must be increased to prevent opening on inrush currents. In such instances, Class T fuses may provide only short circuit protection. For motor and general purpose circuits where space is not critical, we recommend POWR-PRO™ JTD_ID Indicator series, LLNRK/LLSRK series, or FLSR_ID Indicator series.

Specifications

Weight

0.02lb

Height

3mm

Width

1.25mm

Length

3mm

Amperage Rating

40 A

Body Size

0.56 in Dia x 0.875 in L

Body Type

Cartridge

Brand

Littelfuse

Category

Current Limiting Fuses

Class

T

Indicating/Non-Indicating

Non-indicating

Interrupt Rating

20/200 kA

Material

Melamine

Mounting Type

Holder

Series

JLLN

Terminal Type

Ferrule

Type

Current Limiting

Voltage Rating

300 V AC/160 V DC

JLLN040 - JLLN040 - JLLN Series

Picture of JLLN040 - JLLN040 - JLLN Series

JLLN040 - JLLN040 - JLLN Series

Item Code: 11549
Manufacturer Littelfuse
Manufacturer Ref JLLN040
Call for Availability
Compare

Description

Space saving POWR-GARD Class T fuses are the most compact fuses available in ratings above 30 amperes — less than one-third the size of comparable Class R fuses. When rated in accordance with the NEC, Class T fuses provide fast-acting overload and short circuit protection for non-inductive circuits and equipment. Used in inductive circuits, the ampere rating of Class T fuses must be increased to prevent opening on inrush currents. In such instances, Class T fuses may provide only short circuit protection. For motor and general purpose circuits where space is not critical, we recommend POWR-PRO™ JTD_ID Indicator series, LLNRK/LLSRK series, or FLSR_ID Indicator series.

Specifications

Weight

0.02lb

Height

3mm

Width

1.25mm

Length

3mm

Amperage Rating

40 A

Body Size

0.56 in Dia x 0.875 in L

Body Type

Cartridge

Brand

Littelfuse

Category

Current Limiting Fuses

Class

T

Indicating/Non-Indicating

Non-indicating

Interrupt Rating

20/200 kA

Material

Melamine

Mounting Type

Holder

Series

JLLN

Terminal Type

Ferrule

Type

Current Limiting

Voltage Rating

300 V AC/160 V DC