0 CART
items in your cartto quote Checkout
Ooops no items were found.
Try something else.
Ok
Loading…

EX225T6HCT - Transformer, dry type, DOE 2016, 225kVA, 3 phase, 480V delta primary, 240V delta secondary, 25J, 150C rise, 120V ctr

Picture of EX225T6HCT - Transformer, dry type, DOE 2016, 225kVA, 3 phase, 480V delta primary, 240V delta secondary, 25J, 150C rise, 120V ctr

EX225T6HCT - Transformer, dry type, DOE 2016, 225kVA, 3 phase, 480V delta primary, 240V delta secondary, 25J, 150C rise, 120V ctr

Item Code: 1040959
Manufacturer SCHNEIDER ELECTRIC
Manufacturer Ref EX225T6HCT
Call for Availability
Compare

Description

EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 225kVA, 480V primary (three wire), 240/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.94% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.

Specifications

Weight

2057.02

Height

64

Width

39.7

Length

32.45

Brand

Square D

Category

DRY TYPE TRANSFORMERS 600V OR LESS

Dimensions

832 mm L x 1018 mm W x 1461 mm H

Efficiency

DOE 2016 99.04% at 35%

Enclosure Type

NEMA 1/2/3R

Frequency Rating

60 Hz

Insulation

220 DEG C

Mounting Type

Ceiling

Number Of Taps

(2) 2.5% FCAN/(4) 2.5% FCBN

Phase

3

Power Rating

225 KVA

Primary Voltage

480 V delta

Secondary Voltage

240 V Delta Centre Tap 120 V

Temperature Rating

150 Deg C

EX225T6HCT - Transformer, dry type, DOE 2016, 225kVA, 3 phase, 480V delta primary, 240V delta secondary, 25J, 150C rise, 120V ctr

Picture of EX225T6HCT - Transformer, dry type, DOE 2016, 225kVA, 3 phase, 480V delta primary, 240V delta secondary, 25J, 150C rise, 120V ctr

EX225T6HCT - Transformer, dry type, DOE 2016, 225kVA, 3 phase, 480V delta primary, 240V delta secondary, 25J, 150C rise, 120V ctr

Item Code: 1040959
Manufacturer SCHNEIDER ELECTRIC
Manufacturer Ref EX225T6HCT
Call for Availability
Compare

Description

EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 225kVA, 480V primary (three wire), 240/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.94% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.

Specifications

Weight

2057.02

Height

64

Width

39.7

Length

32.45

Brand

Square D

Category

DRY TYPE TRANSFORMERS 600V OR LESS

Dimensions

832 mm L x 1018 mm W x 1461 mm H

Efficiency

DOE 2016 99.04% at 35%

Enclosure Type

NEMA 1/2/3R

Frequency Rating

60 Hz

Insulation

220 DEG C

Mounting Type

Ceiling

Number Of Taps

(2) 2.5% FCAN/(4) 2.5% FCBN

Phase

3

Power Rating

225 KVA

Primary Voltage

480 V delta

Secondary Voltage

240 V Delta Centre Tap 120 V

Temperature Rating

150 Deg C

SEARCH ×