HDA260601 - Circuit breaker, PowerPacT H, 60A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, AB

Category Miscellaneous
Picture of HDA260601 - Circuit breaker, PowerPacT H, 60A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, AB

HDA260601 - Circuit breaker, PowerPacT H, 60A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, AB

Item Code: 1011796
Category Miscellaneous
Manufacturer SCHNEIDER ELECTRIC
Manufacturer Ref HDA260601
Call for Availability
Compare

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 60A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AB phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.

Specifications

Weight

2.99

Width

8.05

Length

14.49

AD All Features

Standard 80% or 100% rating

AD Alternative Part Number

8042890

AD Application

Provides Overload and Short Circuit Protection Applications

AD Brand (Description)

Square Dâ„¢

AD Country

USA

AD Country Of Origin

US

AD Document Caption 1

RoHS

AD Document Caption 2

Specification Sheet

AD Document Caption 3

Owners/User Manual

AD Document Caption 4

Full Engineering Drawing

AD Document Caption 5

Technical Bulletin

AD EAN

0785901419037

AD Gtin

00785901419037

AD IDEA Index ID

8042890

AD Invoice Description

BREAKER CKT CASE MLD 600VAC 250VDC D

AD Item Features 01

Standard 80% or 100% rating

AD Item Features 02

Available in Unit mount, I-line or Drawout constructions

AD Item Features 03

A wide range of accessories, auxiliaries, and lug connections available

AD Keywords

I-Line PowerPact H HDA260601 Type HDA Molded Case Circuit Breaker, 600 V AC/250 V DC, 60 A, 18/14/20/25 kA Interrupt, 2 Poles, Thermal Magnetic Trip ; Schneider Electric ; Square D ; HDA260601 ; HDA260601 ; 785901419037 ; Molded Case Circuit Breakers

AD Manufacturer (Description)

Schneider Electric

AD Package Height UOM

IN

AD Package Length

14.4900

AD Package Length UOM

IN

AD Package Quantity

1

AD Package Weight

2.9900

AD Package Weight UOM

LB

AD Package Width

8.0500

AD Package Width UOM

IN

AD Part Number Keywords

HDA260601 ; 8042890 ; 785901419037 ; 78590141903 ; 00785901419037 ; 0785901419037

AD Video Links

https://www.youtube.com/embed/4wUOBk4oUmk

Brand

Square D

Spec 1 Attribute

Amperage Rating

Spec 1 Attribute UOM

A

Spec 1 Attribute Value

60

Spec 10 Attribute

PHASE

Spec 10 Attribute Value

1

Spec 11 Attribute

Temperature Rating

Spec 11 Attribute UOM

deg C

Spec 11 Attribute Value

40

Spec 12 Attribute

Trip Range

Spec 12 Attribute UOM

A

Spec 12 Attribute Value

60/800/1450

Spec 13 Attribute

Trip Type

Spec 13 Attribute Value

Thermal Magnetic

Spec 14 Attribute

Type

Spec 14 Attribute Value

80% Rated Type HDA

Spec 15 Attribute

Voltage Rating

Spec 15 Attribute Value

600 V AC/250 V DC

Spec 16 Attribute

Wire Size

Spec 16 Attribute UOM

AWG

Spec 16 Attribute Value

14 to 3/0

Spec 2 Attribute

Connection Type

Spec 2 Attribute Value

I-Lineâ„¢/Load Lug/Drawout

Spec 3 Attribute

Dimensions

Spec 3 Attribute Value

4.8 in L x 2.94 in W x 9.73 in H

Spec 4 Attribute

Enclosure Type

Spec 4 Attribute Value

NEMA AB1

Spec 5 Attribute

Frame

Spec 5 Attribute Value

D

Spec 6 Attribute

Frequency Rating

Spec 6 Attribute UOM

HZ

Spec 6 Attribute Value

50/60

Spec 7 Attribute

Interrupt Rating

Spec 7 Attribute Value

18 kA at 480 VAC/25 kA at 240 VAC/14 kA at 600 VAC/20 kA at 250 VDC/250 VDC/600 VAC

Spec 8 Attribute

Mounting Type

Spec 8 Attribute Value

Plug-In

Spec 9 Attribute

Number Of Poles

Spec 9 Attribute Value

2

HDA260601 - Circuit breaker, PowerPacT H, 60A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, AB

Category Miscellaneous
Picture of HDA260601 - Circuit breaker, PowerPacT H, 60A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, AB

HDA260601 - Circuit breaker, PowerPacT H, 60A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, AB

Item Code: 1011796
Category Miscellaneous
Manufacturer SCHNEIDER ELECTRIC
Manufacturer Ref HDA260601
Call for Availability
Compare

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 60A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AB phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.

Specifications

Weight

2.99

Width

8.05

Length

14.49

AD All Features

Standard 80% or 100% rating

AD Alternative Part Number

8042890

AD Application

Provides Overload and Short Circuit Protection Applications

AD Brand (Description)

Square Dâ„¢

AD Country

USA

AD Country Of Origin

US

AD Document Caption 1

RoHS

AD Document Caption 2

Specification Sheet

AD Document Caption 3

Owners/User Manual

AD Document Caption 4

Full Engineering Drawing

AD Document Caption 5

Technical Bulletin

AD EAN

0785901419037

AD Gtin

00785901419037

AD IDEA Index ID

8042890

AD Invoice Description

BREAKER CKT CASE MLD 600VAC 250VDC D

AD Item Features 01

Standard 80% or 100% rating

AD Item Features 02

Available in Unit mount, I-line or Drawout constructions

AD Item Features 03

A wide range of accessories, auxiliaries, and lug connections available

AD Keywords

I-Line PowerPact H HDA260601 Type HDA Molded Case Circuit Breaker, 600 V AC/250 V DC, 60 A, 18/14/20/25 kA Interrupt, 2 Poles, Thermal Magnetic Trip ; Schneider Electric ; Square D ; HDA260601 ; HDA260601 ; 785901419037 ; Molded Case Circuit Breakers

AD Manufacturer (Description)

Schneider Electric

AD Package Height UOM

IN

AD Package Length

14.4900

AD Package Length UOM

IN

AD Package Quantity

1

AD Package Weight

2.9900

AD Package Weight UOM

LB

AD Package Width

8.0500

AD Package Width UOM

IN

AD Part Number Keywords

HDA260601 ; 8042890 ; 785901419037 ; 78590141903 ; 00785901419037 ; 0785901419037

AD Video Links

https://www.youtube.com/embed/4wUOBk4oUmk

Brand

Square D

Spec 1 Attribute

Amperage Rating

Spec 1 Attribute UOM

A

Spec 1 Attribute Value

60

Spec 10 Attribute

PHASE

Spec 10 Attribute Value

1

Spec 11 Attribute

Temperature Rating

Spec 11 Attribute UOM

deg C

Spec 11 Attribute Value

40

Spec 12 Attribute

Trip Range

Spec 12 Attribute UOM

A

Spec 12 Attribute Value

60/800/1450

Spec 13 Attribute

Trip Type

Spec 13 Attribute Value

Thermal Magnetic

Spec 14 Attribute

Type

Spec 14 Attribute Value

80% Rated Type HDA

Spec 15 Attribute

Voltage Rating

Spec 15 Attribute Value

600 V AC/250 V DC

Spec 16 Attribute

Wire Size

Spec 16 Attribute UOM

AWG

Spec 16 Attribute Value

14 to 3/0

Spec 2 Attribute

Connection Type

Spec 2 Attribute Value

I-Lineâ„¢/Load Lug/Drawout

Spec 3 Attribute

Dimensions

Spec 3 Attribute Value

4.8 in L x 2.94 in W x 9.73 in H

Spec 4 Attribute

Enclosure Type

Spec 4 Attribute Value

NEMA AB1

Spec 5 Attribute

Frame

Spec 5 Attribute Value

D

Spec 6 Attribute

Frequency Rating

Spec 6 Attribute UOM

HZ

Spec 6 Attribute Value

50/60

Spec 7 Attribute

Interrupt Rating

Spec 7 Attribute Value

18 kA at 480 VAC/25 kA at 240 VAC/14 kA at 600 VAC/20 kA at 250 VDC/250 VDC/600 VAC

Spec 8 Attribute

Mounting Type

Spec 8 Attribute Value

Plug-In

Spec 9 Attribute

Number Of Poles

Spec 9 Attribute Value

2

SEARCH ×