0 CART
items in your cartto quote Checkout
Ooops no items were found.
Try something else.
Ok
Loadingâ€Ĥ

PGA36080CU31A - Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 3.0, 100%, ABC

Picture of PGA36080CU31A - Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 3.0, 100%, ABC

PGA36080CU31A - Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 3.0, 100%, ABC

Item Code: 759036
Manufacturer SCHNEIDER ELECTRIC
Manufacturer Ref PGA36080CU31A
Call for Availability
Compare

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.

Specifications

Weight

31.93

Width

11.52

Length

20.06

Amperage Rating

800 A

Brand

Square D

Category

ELECTRONIC TRIP MOLDED CASE CIRCUIT BREAKERS

Connection Type

Load Lug/Plug-On

Dimensions

8.1 in L x 8.3 in W x 16.2 in H

Enclosure Type

NEMA AB1

Frame

P

Frequency Rating

50/60 Hz

Interrupt Rating

65 kA at 240 VAC, 35 kA at 480 VAC, 18 kA at 600 VAC

Mounting Type

Busbar

Number Of Poles

3

Phase

3

Temperature Rating

104 deg F

Trip Range

100 to 1200 A

Trip Type

Electronic

Type

Type PGA

Voltage Rating

600 V AC

Wire Size

3/0 AWG to 500 kcmil Al, 3 AWG Cu

PGA36080CU31A - Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 3.0, 100%, ABC

Picture of PGA36080CU31A - Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 3.0, 100%, ABC

PGA36080CU31A - Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 3.0, 100%, ABC

Item Code: 759036
Manufacturer SCHNEIDER ELECTRIC
Manufacturer Ref PGA36080CU31A
Call for Availability
Compare

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.

Specifications

Weight

31.93

Width

11.52

Length

20.06

Amperage Rating

800 A

Brand

Square D

Category

ELECTRONIC TRIP MOLDED CASE CIRCUIT BREAKERS

Connection Type

Load Lug/Plug-On

Dimensions

8.1 in L x 8.3 in W x 16.2 in H

Enclosure Type

NEMA AB1

Frame

P

Frequency Rating

50/60 Hz

Interrupt Rating

65 kA at 240 VAC, 35 kA at 480 VAC, 18 kA at 600 VAC

Mounting Type

Busbar

Number Of Poles

3

Phase

3

Temperature Rating

104 deg F

Trip Range

100 to 1200 A

Trip Type

Electronic

Type

Type PGA

Voltage Rating

600 V AC

Wire Size

3/0 AWG to 500 kcmil Al, 3 AWG Cu

SEARCH ×