RGA36120CU31A - Circuit breaker, PowerPacT R, 1200A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 3.0, 100%

Picture of RGA36120CU31A - Circuit breaker, PowerPacT R, 1200A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 3.0, 100%

RGA36120CU31A - Circuit breaker, PowerPacT R, 1200A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 3.0, 100%

Item Code: 635815
Manufacturer SCHNEIDER ELECTRIC
Manufacturer Ref RGA36120CU31A
Call for Availability
Compare

Description

PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard Trip with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.

Specifications

Weight

49.05

Height

12.7

Width

19.81

Length

19.61

Amperage Rating

1200 A

Brand

Square D

Category

ELECTRONIC TRIP MOLDED CASE CIRCUIT BREAKERS

Connection Type

Line/Load Lug

Dimensions

13.38 in H x 14.96 in W x 13.78 in D

Enclosure Type

NEMA AB1

Frame

R

Frequency Rating

50/60 Hz

Interrupt Rating

65 kA at 240 VAC, 35 kA at 480 VAC, 18 kA at 600 VAC

Mounting Type

Plug-On

Number Of Poles

3

Phase

3

Temperature Rating

104 deg F

Trip Range

240 to 3000 A

Trip Type

Electronic

Type

100% Rated

Voltage Rating

600 V AC

Wire Size

3/0 AWG to 600 kcmil Al/Cu

RGA36120CU31A - Circuit breaker, PowerPacT R, 1200A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 3.0, 100%

Picture of RGA36120CU31A - Circuit breaker, PowerPacT R, 1200A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 3.0, 100%

RGA36120CU31A - Circuit breaker, PowerPacT R, 1200A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 3.0, 100%

Item Code: 635815
Manufacturer SCHNEIDER ELECTRIC
Manufacturer Ref RGA36120CU31A
Call for Availability
Compare

Description

PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard Trip with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.

Specifications

Weight

49.05

Height

12.7

Width

19.81

Length

19.61

Amperage Rating

1200 A

Brand

Square D

Category

ELECTRONIC TRIP MOLDED CASE CIRCUIT BREAKERS

Connection Type

Line/Load Lug

Dimensions

13.38 in H x 14.96 in W x 13.78 in D

Enclosure Type

NEMA AB1

Frame

R

Frequency Rating

50/60 Hz

Interrupt Rating

65 kA at 240 VAC, 35 kA at 480 VAC, 18 kA at 600 VAC

Mounting Type

Plug-On

Number Of Poles

3

Phase

3

Temperature Rating

104 deg F

Trip Range

240 to 3000 A

Trip Type

Electronic

Type

100% Rated

Voltage Rating

600 V AC

Wire Size

3/0 AWG to 600 kcmil Al/Cu