S29390 - Circuit breaker accessory, PowerPacT H/J/L, shunt trip, 24VDC

Picture of S29390 - Circuit breaker accessory, PowerPacT H/J/L, shunt trip, 24VDC

S29390 - Circuit breaker accessory, PowerPacT H/J/L, shunt trip, 24VDC

Item Code: 720575
Manufacturer SCHNEIDER ELECTRIC
Manufacturer Ref S29390
Call for Availability
Compare

Description

The PowerPacT™ H-, J-, and L-frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. H- and J-frame circuit breakers are available with either thermal-magnetic or Micrologic™ electronic trip units. L-frame circuit breakers are available with Micrologic electronic trip units only. Shunt Trip (MX). Trips the circuit breaker when the control voltage rises above 70% of its rated voltage. Impulse type ≥ 20 ms or maintained control signals. AC shunt trips are suitable for ground-fault protection when combined with a Class I ground-fault sensing element. Continuous duty rated coil.

Specifications

Weight

0.28

Width

3.07

Length

4.46

Brand

Square D

Category

Circuit Breaker Accessories

Suitable For Use With

PowerPact™ H, J and L Frame Molded Case Circuit Breaker

Voltage Rating

24 V DC

S29390 - Circuit breaker accessory, PowerPacT H/J/L, shunt trip, 24VDC

Picture of S29390 - Circuit breaker accessory, PowerPacT H/J/L, shunt trip, 24VDC

S29390 - Circuit breaker accessory, PowerPacT H/J/L, shunt trip, 24VDC

Item Code: 720575
Manufacturer SCHNEIDER ELECTRIC
Manufacturer Ref S29390
Call for Availability
Compare

Description

The PowerPacT™ H-, J-, and L-frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. H- and J-frame circuit breakers are available with either thermal-magnetic or Micrologic™ electronic trip units. L-frame circuit breakers are available with Micrologic electronic trip units only. Shunt Trip (MX). Trips the circuit breaker when the control voltage rises above 70% of its rated voltage. Impulse type ≥ 20 ms or maintained control signals. AC shunt trips are suitable for ground-fault protection when combined with a Class I ground-fault sensing element. Continuous duty rated coil.

Specifications

Weight

0.28

Width

3.07

Length

4.46

Brand

Square D

Category

Circuit Breaker Accessories

Suitable For Use With

PowerPact™ H, J and L Frame Molded Case Circuit Breaker

Voltage Rating

24 V DC