0 CART
items in your cartto quote Checkout
Ooops no items were found.
Try something else.
Ok
Loading…

SC2040M125PF - All in one, Homeline, combination service entrance, ringed socket, 125A, semi flush, 20 spaces, 40 circuits, 10kA SSCR, OH, UG, no bypass, solar ready

Category Miscellaneous
Picture of SC2040M125PF - All in one, Homeline, combination service entrance, ringed socket, 125A, semi flush, 20 spaces, 40 circuits, 10kA SSCR, OH, UG, no bypass, solar ready Picture of SC2040M125PF - All in one, Homeline, combination service entrance, ringed socket, 125A, semi flush, 20 spaces, 40 circuits, 10kA SSCR, OH, UG, no bypass, solar ready
Picture of SC2040M125PF - All in one, Homeline, combination service entrance, ringed socket, 125A, semi flush, 20 spaces, 40 circuits, 10kA SSCR, OH, UG, no bypass, solar ready Picture of SC2040M125PF - All in one, Homeline, combination service entrance, ringed socket, 125A, semi flush, 20 spaces, 40 circuits, 10kA SSCR, OH, UG, no bypass, solar ready
Picture of SC2040M125PF - All in one, Homeline, combination service entrance, ringed socket, 125A, semi flush, 20 spaces, 40 circuits, 10kA SSCR, OH, UG, no bypass, solar ready Picture of SC2040M125PF - All in one, Homeline, combination service entrance, ringed socket, 125A, semi flush, 20 spaces, 40 circuits, 10kA SSCR, OH, UG, no bypass, solar ready

SC2040M125PF - All in one, Homeline, combination service entrance, ringed socket, 125A, semi flush, 20 spaces, 40 circuits, 10kA SSCR, OH, UG, no bypass, solar ready

Item Code: 972419
Category Miscellaneous
Manufacturer SCHNEIDER ELECTRIC
Manufacturer Ref SC2040M125PF
Call for Availability
Compare

Description

Homeline All In One combination service entrance devices are available with ring or ringless type meter socket designs. Devices have factory installed service disconnect(s) in most cases. Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires. These Homeline combination service entrance devices meet the Federal Specification W P 115c as Type 1, Class 2 specifications. This Homeline All In One combination service entrance device has a ringed meter socket with no bypass. This unit can be feed from an overhead service with the addition of tunnel kit (SCTKP20) or underground service. The service disconnect has a QOM2125VH with a maximum rating of 125 A. Device has a 22 kA short circuit current rating. Load center has 20 spaces which will accept up to 20 tandem Homeline circuit breakers. This unit has a NEMA 3R semi flush mount enclosure that is 39.80 inches tall, 16.80 inches wide and 3.40 inches deep. The line side lugs will accept 4 AWG to 250 kcmil copper or aluminum wire. The service ground lug will accept 8 AWG to 2/0 AWG copper or aluminum wire. This Homeline All In One combination service entrance meter main unit is UL Listed. Device meets EUSERC standards.

Specifications

Weight

54.78

Width

17.43

Length

40.12

Amperage Rating

125 A

Brand

Square D

Cover Type

Ringed

Dimensions

16.8 in W x 3.4 in D x 39.8 in H

Feed Type

Overhead/Underground

Hub Type

A-L

Mounting Type

Flush

Phase

1

Terminal Type

Plug-on neutral

Type

All-in-One 20-Cutout 20-Space 40-Circuit

Wire Size

8 to 2/0 AWG

SC2040M125PF - All in one, Homeline, combination service entrance, ringed socket, 125A, semi flush, 20 spaces, 40 circuits, 10kA SSCR, OH, UG, no bypass, solar ready

Category Miscellaneous
Picture of SC2040M125PF - All in one, Homeline, combination service entrance, ringed socket, 125A, semi flush, 20 spaces, 40 circuits, 10kA SSCR, OH, UG, no bypass, solar ready Picture of SC2040M125PF - All in one, Homeline, combination service entrance, ringed socket, 125A, semi flush, 20 spaces, 40 circuits, 10kA SSCR, OH, UG, no bypass, solar ready
Picture of SC2040M125PF - All in one, Homeline, combination service entrance, ringed socket, 125A, semi flush, 20 spaces, 40 circuits, 10kA SSCR, OH, UG, no bypass, solar ready Picture of SC2040M125PF - All in one, Homeline, combination service entrance, ringed socket, 125A, semi flush, 20 spaces, 40 circuits, 10kA SSCR, OH, UG, no bypass, solar ready
Picture of SC2040M125PF - All in one, Homeline, combination service entrance, ringed socket, 125A, semi flush, 20 spaces, 40 circuits, 10kA SSCR, OH, UG, no bypass, solar ready Picture of SC2040M125PF - All in one, Homeline, combination service entrance, ringed socket, 125A, semi flush, 20 spaces, 40 circuits, 10kA SSCR, OH, UG, no bypass, solar ready

SC2040M125PF - All in one, Homeline, combination service entrance, ringed socket, 125A, semi flush, 20 spaces, 40 circuits, 10kA SSCR, OH, UG, no bypass, solar ready

Item Code: 972419
Category Miscellaneous
Manufacturer SCHNEIDER ELECTRIC
Manufacturer Ref SC2040M125PF
Call for Availability
Compare

Description

Homeline All In One combination service entrance devices are available with ring or ringless type meter socket designs. Devices have factory installed service disconnect(s) in most cases. Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires. These Homeline combination service entrance devices meet the Federal Specification W P 115c as Type 1, Class 2 specifications. This Homeline All In One combination service entrance device has a ringed meter socket with no bypass. This unit can be feed from an overhead service with the addition of tunnel kit (SCTKP20) or underground service. The service disconnect has a QOM2125VH with a maximum rating of 125 A. Device has a 22 kA short circuit current rating. Load center has 20 spaces which will accept up to 20 tandem Homeline circuit breakers. This unit has a NEMA 3R semi flush mount enclosure that is 39.80 inches tall, 16.80 inches wide and 3.40 inches deep. The line side lugs will accept 4 AWG to 250 kcmil copper or aluminum wire. The service ground lug will accept 8 AWG to 2/0 AWG copper or aluminum wire. This Homeline All In One combination service entrance meter main unit is UL Listed. Device meets EUSERC standards.

Specifications

Weight

54.78

Width

17.43

Length

40.12

Amperage Rating

125 A

Brand

Square D

Cover Type

Ringed

Dimensions

16.8 in W x 3.4 in D x 39.8 in H

Feed Type

Overhead/Underground

Hub Type

A-L

Mounting Type

Flush

Phase

1

Terminal Type

Plug-on neutral

Type

All-in-One 20-Cutout 20-Space 40-Circuit

Wire Size

8 to 2/0 AWG

SEARCH ×